Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Usual-paced 400?m long distance corridor walk estimates cardiorespiratory fitness among older adults: The Study of Muscle, Mobility and Aging.

Garcia RE, Cawthon PM, Nicklas BJ, Goodpaster BH, Coen PM, Forman DE, Cummings SR, Newman AB, Glynn NW. Usual-paced 400?m long distance corridor walk estimates cardiorespiratory fitness among older adults: The Study of Muscle, Mobility and Aging. Journal of the American Geriatrics Society. 2024 Mar 1; 72(3):858-865.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Cardiopulmonary exercise testing (CPET), the gold-standard method to quantify cardiorespiratory fitness (CRF), is not always feasible due to cost, access, and burden. The usual-paced 400?m long distance corridor walk (LDCW), a measure of mobility among older adults, may provide an alternate method to assess CRF. The purpose of this study was to develop and validate an estimating equation to estimate VO peak from average 400?m walking speed (WS) among participants in the Study of Muscle, Mobility and Aging (SOMMA). METHODS: At baseline, women (58%) and men age 70?years and older enrolled in SOMMA (N? = 820, 76.2?±?4.9?years, 86% Non-Hispanic White) completed a 400?m LDCW (400?m WS? = 400?m/completion time in seconds) and symptom-limited maximal CPET (Modified Balke Protocol). VO peak (mL/kg/min) was considered the highest 30-second average oxygen consumption during CPET. Other covariates included: age, sex, race, physical activity (7-day wrist-worn accelerometer), physical function (Short Physical Performance Battery, range 0-12), perceived physical fatigability (Pittsburgh Fatigability Scale, range 0-50), and Borg Rating of Perceived Exertion (RPE, range 6-20) at completion of the 400?m LDCW. Stepwise linear regression was used. Internal validation was completed using data-splitting method (70%; 30%). RESULTS: Mean VO peak was 20.2?±?4.8?mL/kg/min and mean 400?m WS was 1.06?±?0.2?m/s. Each 0.05?m/s increment in 400?m WS was associated with a 0.40?mL/kg/min higher VO peak after covariate adjustment. An estimating equation including 400?m WS, age, sex, race, and RPE was developed. Internal validation showed low overall bias (-0.26) and strong correlation (r? = 0.71) between predicted and measured VO peak values. Bland-Altman plot and regression analyses indicated predicted VO peak was an acceptable alternative, despite mean underestimation of 4.53?mL/kg/min among the highly fit. CONCLUSIONS: Usual-paced 400?m LDCW strongly correlates with direct measures of CRF during CPET in older adults with lower fitness and can be used to test both fitness and function.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.