Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Revision Hip Arthroplasty Using a Modular, Cementless Femoral Stem: Intermediate-Term Follow-Up.

Sivananthan S, Lim CT, Narkbunnam R, Sox-Harris A, Huddleston JI, Goodman SB. Revision Hip Arthroplasty Using a Modular, Cementless Femoral Stem: Intermediate-Term Follow-Up. Journal of Arthroplasty. 2017 Apr 1; 32(4):1245-1249.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Modular femoral stem provides flexibility in femoral reconstruction, ensuring improved "fit and fill". However, there are risks of junction failure and corrosion, as well as cost concerns in the use of modular femoral stems. METHODS: We reviewed prospectively-gathered clinical and radiographic data on revision total hip arthroplasties (THAs) performed from 2001-2007 using modular, cementless femoral component performed by the 2 senior authors. Patients with a minimum follow-up of 7 years were included in this study. RESULTS: Sixty-four patients (68 hips) with a median age of 68 ± 14 years (range 40-92 years) at revision THA were included. The median follow-up was 11.0 ± 1.8 years (range 7-14). Harris hip score, femoral stem subsidence, and stem osseointegration were recorded. The Harris hip score improved from an average of 38.1-80.1 (P < .01). Five hips had one or more dislocations. Seven patients underwent reoperations, 3 of which did not involve the stem. Four stems required revision because of infection, recurrent dislocation, or suboptimal implant position. Survival rates for any reasons and revision for femoral stems were 90% and 94%, respectively, at the most recent follow-up. Four stems subsided more than 5 mm, but established stable osseointegration thereafter. Seven nonloose stems (10.2%) demonstrated radiolucent lines in Gruen zones 1 and 7. No complications regarding the modular junction were encountered. CONCLUSION: Modular, cementless, extensively porous-coated femoral components have demonstrated intermediate-term clinical and radiographic success. Initial distal intramedullary fixation ensures stability, and proximal modularity further maximizes fit and fill.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.