Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

A human factors approach to improving electronic performance measurement of venous thromboembolism prophylaxis.

Horstman MJ, Cowart JB, Mcmaster-Baxter NL, Trautner BW, Stewart DE. A human factors approach to improving electronic performance measurement of venous thromboembolism prophylaxis. International journal for quality in health care : journal of the International Society for Quality in Health Care. 2016 Feb 1; 28(1):59-65.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

OBJECTIVE: In 2011, our institution developed a venous thromboembolism (VTE) prophylaxis order set to monitor prophylaxis management through physician-generated risk assessment orders. Prophylaxis rates obtained using the risk assessment orders were falsely low compared with chart review. Our goal was to redesign the order set to increase the percentage of VTE risk assessments ordered, both to improve care and to better reflect performance. DESIGN: Quality Improvement Project. SETTING: Veterans Health Administration. PARTICIPANTS: Patients admitted to acute care and intensive care medical units. INTERVENTIONS: Process analysis was used to identify systems failures limiting use of the original order set. The order set was redesigned using a human factors approach. MAIN OUTCOME MEASURE: VTE risk assessment orders. RESULTS: The order set was redesigned to reduce complexity and improve integration into provider workflow. The rate of risk assessment orders placed within 24 h increased from 48.6 to 80.4% (P < 0.001). There was no difference in the actual use of prophylaxis. However, for patients on prophylaxis, the rates of having a documented 'moderate' or 'high' risk assessment within 24 h increased from 66.7 to 95.7% (P < 0.001). CONCLUSIONS: Using human factor principles to redesign an order set led to a significant increase in the percentage of patients with a risk assessment order placed within 24 h of admission. Although the risk assessments using the redesigned order set better reflected physician performance, it remained an imperfect measure for VTE prophylaxis. New technology used to measure human performance must be evaluated following implementation to assess accuracy.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.