Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Evaluation of an automated safety surveillance system using risk adjusted sequential probability ratio testing.

Matheny ME, Normand SL, Gross TP, Marinac-Dabic D, Loyo-Berrios N, Vidi VD, Donnelly S, Resnic FS. Evaluation of an automated safety surveillance system using risk adjusted sequential probability ratio testing. BMC medical informatics and decision making. 2011 Dec 14; 11:75.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Automated adverse outcome surveillance tools and methods have potential utility in quality improvement and medical product surveillance activities. Their use for assessing hospital performance on the basis of patient outcomes has received little attention. We compared risk-adjusted sequential probability ratio testing (RA-SPRT) implemented in an automated tool to Massachusetts public reports of 30-day mortality after isolated coronary artery bypass graft surgery. METHODS: A total of 23,020 isolated adult coronary artery bypass surgery admissions performed in Massachusetts hospitals between January 1, 2002 and September 30, 2007 were retrospectively re-evaluated. The RA-SPRT method was implemented within an automated surveillance tool to identify hospital outliers in yearly increments. We used an overall type I error rate of 0.05, an overall type II error rate of 0.10, and a threshold that signaled if the odds of dying 30-days after surgery was at least twice than expected. Annual hospital outlier status, based on the state-reported classification, was considered the gold standard. An event was defined as at least one occurrence of a higher-than-expected hospital mortality rate during a given year. RESULTS: We examined a total of 83 hospital-year observations. The RA-SPRT method alerted 6 events among three hospitals for 30-day mortality compared with 5 events among two hospitals using the state public reports, yielding a sensitivity of 100% (5/5) and specificity of 98.8% (79/80). CONCLUSIONS: The automated RA-SPRT method performed well, detecting all of the true institutional outliers with a small false positive alerting rate. Such a system could provide confidential automated notification to local institutions in advance of public reporting providing opportunities for earlier quality improvement interventions.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.