Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Accuracy of a urinary catheter surveillance protocol.

Burns AC, Petersen NJ, Garza A, Arya M, Patterson JE, Naik AD, Trautner BW. Accuracy of a urinary catheter surveillance protocol. American journal of infection control. 2012 Feb 1; 40(1):55-8.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Many hospitals are increasing surveillance for catheter-associated urinary tract infections, which requires documentation of urinary catheter device-days. However, device-days are usually obtained by chart review or nursing reports. The aim of this study was to demonstrate that chart review can provide accurate urinary catheter data compared with physical inspection of the urinary catheter at the bedside. METHODS: We compared 2 methods for collecting urinary catheter data over a 6-month period on 10 wards at our VA hospital. For the chart reviews, we created a daily bed-occupancy roster from the electronic medical record. Catheter data were extracted from the daily progress notes for each patient using a standardized review process. Bedside reviews were conducted by visiting the ward and verifying the presence and type of urinary catheters. Agreement between the 2 methods was calculated. RESULTS: We obtained urinary catheter data by both methods in 621 cases. The presence or type of urinary catheter differed between chart and bedside review in only 10 cases (1.6%). Chart review had a sensitivity of 100%, a specificity of 97.7%, raw agreement of 98.4%, and a value of 0.96. CONCLUSIONS: Individual chart review in the electronic medical record provided very accurate data on urinary catheter use.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.