Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Validity and reliability of a short self-efficacy instrument for hypertension treatment adherence among adults with uncontrolled hypertension.

Zhao M, Rodriguez MA, Wang B, Santa Ana EJ, Friedberg J, Fang Y, Allegrante JP, Natarajan S. Validity and reliability of a short self-efficacy instrument for hypertension treatment adherence among adults with uncontrolled hypertension. Patient education and counseling. 2021 Jul 1; 104(7):1781-1788.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

OBJECTIVE: To establish the reliability and validity of a self-report measure designed to assess self-efficacy for hypertension treatment adherence. METHODS: This investigation was embedded within a six-month randomized clinical trial (RCT), which demonstrated that a tailored, stage-matched intervention was more effective at improving hypertension control than usual care among individuals (n? = 533) with repeated uncontrolled hypertension. The instrument used to assess self-efficacy for hypertension treatment adherence (SE-HTA) comprised three subscales that assessed diet self-efficacy (DSE), exercise self-efficacy (ESE), and medication self-efficacy (MSE). To determine SE-HTA validity and reliability, we assessed internal consistency using Cronbach's a coefficients, conducted exploratory factor analysis, and evaluated convergent and discriminant validity, as well as test-retest reliability using Spearman's ? correlation coefficients. RESULTS: Cronbach's a (internal consistency) values for DSE, ESE, and MSE were 0.81, 0.82 and 0.74. Factor analysis and the scree plot demonstrated three distinct factors, which correspond to the three subscales contained in the SE-HTA instrument. SE-HTA possessed good convergent and discriminant validity, and moderate test-retest reliability. CONCLUSION: The SE-HTA instrument containing diet, exercise, and medication adherence subscales is valid and reliable in adults with uncontrolled hypertension. PRACTICE IMPLICATIONS: This SE-HTA instrument measures self-efficacy and could help facilitate behavior change in hypertension.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.