Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Interlocking screw configuration influences distal tibial fracture stability in torsional loading after intramedullary nailing.

Lowenberg DW, DeBaun MR, Behn A, Sox-Harris A. Interlocking screw configuration influences distal tibial fracture stability in torsional loading after intramedullary nailing. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2020 Oct 1; 30(7):1205-1213.

Related HSR&D Project(s)

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

PURPOSE: This study evaluated the influence of fracture obliquity and locking screw configuration on interfragmentary motion during torsional loading of distal metaphyseal tibial fractures fixed by intramedullary (IM) nailing. METHODS: The stability of six IM nail locking screw configurations used to fix distal metaphyseal tibial fractures of various obliquities was evaluated. A coronal osteotomy from proximal lateral to distal medial was made in sawbone tibiae at different obliquities from 0° to 60°. After fixation, motion at the fracture was assessed during internal and external rotation tests to 7 Nm under two compressive loading conditions: 20 N and 500 N. RESULTS: With results organized by interlocking configuration, significant differences in interfragmentary rotation between fracture obliquities are observed when the number of interlocking screws is decreased to one distal static and one proximal dynamic during internal rotation. During external rotation testing, significant rotational differences between fracture obliquities are encountered with two distal static screws and one proximal dynamic. No significant differences were seen between different distal interlocking screw orientations (two parallel versus perpendicular distal screws) for all fracture obliquity patterns tested. CONCLUSION: Fracture obliquity influences rotational stability which can be mitigated by interlocking screw configurations when nailing distal tibia fractures. At least two distal and one proximal interlocking screw in a static mode is recommended to resist torsional loading of distal tibia fractures undergoing intramedullary nailing. The addition of more interlocking screws than this did not significantly alter control of torsional displacement with load.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.