Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

A novel noninvasive method for remote heart failure monitoring: the EuleriAn video Magnification apPLications In heart Failure studY (AMPLIFY).

Abnousi F, Kang G, Giacomini J, Yeung A, Zarafshar S, Vesom N, Ashley E, Harrington R, Yong C. A novel noninvasive method for remote heart failure monitoring: the EuleriAn video Magnification apPLications In heart Failure studY (AMPLIFY). NPJ digital medicine. 2019 Aug 21; 2:80.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

Current remote monitoring devices for heart failure have been shown to reduce hospitalizations but are invasive and costly; accurate non-invasive options remain limited. The EuleriAn Video Magnification ApPLications In Heart Failure StudY (AMPLIFY) pilot aimed to evaluate the accuracy of a novel noninvasive method that uses Eulerian video magnification. Video recordings were performed on the neck veins of 50 patients who were scheduled for right heart catheterization at the Palo Alto VA Medical Center. The recorded jugular venous pulsations were then enhanced by applying Eulerian phase-based motion magnification. Assessment of jugular venous pressure was compared across three categories: (1) physicians who performed bedside exams, (2) physicians who reviewed both the amplified and unamplified videos, and (3) direct invasive measurement of right atrial pressure from right heart catheterization. Motion magnification reduced inaccuracy of the clinician assessment of central venous pressure compared to the gold standard of right heart catheterization (mean discrepancy of -0.80?cm HO; 95% CI -2.189 to 0.612, ? = 0.27) when compared to both unamplified video (-1.84?cm HO; 95% CI -3.22 to -0.46, ? = 0.0096) and the bedside exam (-2.90?cm HO; 95% CI -4.33 to 1.40, ? = 0.0002). Major categorical disagreements with right heart catheterization were significantly reduced with motion magnification (12%) when compared to unamplified video (25%) or the bedside exam (27%). This novel method of assessing jugular venous pressure improves the accuracy of the clinical exam and may enable accurate remote monitoring of heart failure patients with minimal patient risk.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.