Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

The Association of an Upper Extremity Functional Survey and Glaucoma Medication Administration Success.

Hein AM, Rosdahl JA, Bosworth HB, Woolson SL, Olsen MK, Kirshner MA, Muir KW. The Association of an Upper Extremity Functional Survey and Glaucoma Medication Administration Success. Current eye research. 2019 Oct 1; 44(10):1150-1156.

Related HSR&D Project(s)

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

: To determine if an upper extremity functional survey may identify which patients will have eye drop administration difficulty. : Participants with glaucoma treated at a Veterans Affairs Eye Clinic who did not self-report 100% medication adherence were enrolled in a cross-sectional study. Participants were scored on their observed ability to place a drop into the eye (accuracy) and express no more than one drop from the bottle (efficiency). Successful execution of both of these conditions was defined as good drop technique. Participants also completed the QuickDASH, a validated upper extremity functional survey, with higher scores indicating worse disability. We hypothesized participants with lower QuickDASH scores would have an increased probability of observed success with drop administration measures. Diagnoses of upper extremity co-morbidities were abstracted from participants'' medical records and clustered into diagnostic groups of either neurologic or musculoskeletal etiologies. : When observed, 80 of 94 participants displayed successful accuracy, 58 of 94 participants displayed successful efficiency, and 50 of 94 participants displayed good drop technique. Accuracy with eye drop performance was not related to QuickDASH scores (odds ratio (OR) [probability of successful administration per 10-point decrease in QuickDASH score]: 1.14, 95% CI: 0.89-1.45, =  .29). Success with drop administration efficiency was strongly associated with QuickDASH score (OR: 1.27, 95% CI: 1.04-1.54, =  .02), as was good drop technique (OR: 1.28, 95% CI: 1.05-1.56, =  .01), with lower (better) QuickDASH scores associated with better drop technique. There were no associations between upper extremity neurologic or musculoskeletal co-morbidities and observed good drop technique. The presence of either a neurologic or musculoskeletal upper extremity co-morbidity in a participant''s medical record was associated with a higher QuickDASH score. : The QuickDASH survey may identify patients with eye drop administration difficulties so this population receives focused drop technique education and management strategies. : CPRS: Computerized Patient Records System; MSK: musculoskeletal; UE: upper extremity; VA: Veterans Affairs.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.