Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Deformable image registration-based contour propagation yields clinically acceptable plans for MRI-based cervical cancer brachytherapy planning.

Chapman CH, Polan D, Vineberg K, Jolly S, Maturen KE, Brock KK, Prisciandaro JI. Deformable image registration-based contour propagation yields clinically acceptable plans for MRI-based cervical cancer brachytherapy planning. Brachytherapy. 2018 Mar 1; 17(2):360-367.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

PURPOSE: To study the dosimetric impact of deformable image registration-based contour propagation on MRI-based cervical cancer brachytherapy planning. METHODS AND MATERIALS: High-risk clinical target volume (HRCTV) and organ-at-risk (OAR) contours were delineated on MR images of 10 patients who underwent ring and tandem brachytherapy. A second set of contours were propagated using a commercially available deformable registration algorithm. "Manual-contour" and "propagated-contour" plans were optimized to achieve a maximum dose to the most minimally exposed 90% of the volume (D) (%) of 6 Gy/fraction, respecting minimum dose to the most exposed 2cc of the volume (D) OAR constraints of 5.25 Gy and 4.2 Gy/fraction for bladder and rectum/sigmoid (86.5 and 73.4 Gy equivalent dose in 2 Gy fractions [EQD] for external beam radiotherapy [EBRT] + brachytherapy, respectively). Plans were compared using geometric and dosimetric (total dose [EQD] EBRT + brachytherapy) parameters. RESULTS: The differences between the manual- and propagated-contour plans with respect to the HRCTV D and bladder, rectum, and sigmoid D were not statistically significant (per-fraction basis). For the EBRT + brachytherapy course, the D delivered to the manually contoured OARs by the propagated-contour plans ranging 98-107%, 95-105%, and 92-108% of the dose delivered by the manual-contour plans (max 90.4, 70.3, and 75.4 Gy for the bladder, rectum, and sigmoid, respectively). The HRCTV dose in the propagated-contour plans was 97-103% of the dose in the manual-contour plans (maximum difference 2.92 Gy). Increased bladder filling resulted in increased bladder dose in manual- and propagated-contour plans. CONCLUSIONS: When deformable image registration-propagated contours are used for cervical brachytherapy planning, the HRCTV dose is similar to the dose delivered by manual-contour plans and the doses delivered to the OARs are clinically acceptable, suggesting that our algorithm can replace manual contouring for appropriately selected cases that lack major interfractional anatomical changes.