Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Drug-eluting stents versus bare-metal stents in saphenous vein grafts: a double-blind, randomised trial.

Brilakis ES, Edson R, Bhatt DL, Goldman S, Holmes DR, Rao SV, Shunk K, Rangan BV, Mavromatis K, Ramanathan K, Bavry AA, Garcia S, Latif F, Armstrong E, Jneid H, Conner TA, Wagner T, Karacsonyi J, Uyeda L, Ventura B, Alsleben A, Lu Y, Shih MC, Banerjee S, DIVA Trial Investigators. Drug-eluting stents versus bare-metal stents in saphenous vein grafts: a double-blind, randomised trial. Lancet (London, England). 2018 May 19; 391(10134):1997-2007.

Related HSR&D Project(s)

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Few studies have examined the efficacy of drug-eluting stents (DES) for reducing aortocoronary saphenous vein bypass graft (SVG) failure compared with bare-metal stents (BMS) in patients undergoing stenting of de-novo SVG lesions. We assessed the risks and benefits of the use of DES versus BMS in de-novo SVG lesions. METHODS: Patients were recruited to our double-blind, randomised controlled trial from 25 US Department of Veterans Affairs centres. Eligible participants were aged at least 18 years and had at least one significant de-novo SVG lesion (50-99% stenosis of a 2·25-4·5 mm diameter SVG) requiring percutaneous coronary intervention with intent to use embolic protection devices. Enrolled patients were randomly assigned, in a 1:1 ratio, by phone randomisation system to receive a DES or BMS. Randomisation was stratified by presence or absence of diabetes and number of target SVG lesions requiring percutaneous coronary intervention (one or two or more) within each participating site by use of an adaptive scheme intended to balance the two stent type groups on marginal totals for the stratification factors. Patients, referring physicians, study coordinators, and outcome assessors were masked to group allocation. The primary endpoint was the 12-month incidence of target vessel failure, defined as the composite of cardiac death, target vessel myocardial infarction, or target vessel revascularisation. The DIVA trial is registered with ClinicalTrials.gov, number NCT01121224. FINDINGS: Between Jan 1, 2012, and Dec 31, 2015, 599 patients were randomly assigned to the stent groups, and the data for 597 patients were used. The patients' mean age was 68·6 (SD 7·6) years, and 595 ( > 99%) patients were men. The two stent groups were similar for most baseline characteristics. At 12 months, the incidence of target vessel failure was 17% (51 of 292) in the DES group versus 19% (58 of 305) in the BMS group (adjusted hazard ratio 0·92, 95% CI 0·63-1·34, p = 0·70). Between-group differences in the components of the primary endpoint, serious adverse events, or stent thrombosis were not significant. Enrolment was stopped before the revised target sample size of 762 patients was reached. INTERPRETATION: In patients undergoing stenting of de-novo SVG lesions, no significant differences in outcomes between those receiving DES and BMS during 12 months of follow-up were found. The study results have important economic implications in countries with high DES prices such as the USA, because they suggest that the lower-cost BMS can be used in SVG lesions without compromising either safety or efficacy. FUNDING: US Department of Veterans Affairs Cooperative Studies Program.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.