Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Rupture rate of large abdominal aortic aneurysms in patients refusing or unfit for elective repair.

Lederle FA, Johnson GR, Wilson SE, Ballard DJ, Jordan WD, Blebea J, Littooy FN, Freischlag JA, Bandyk D, Rapp JH, Salam AA. Rupture rate of large abdominal aortic aneurysms in patients refusing or unfit for elective repair. JAMA : the journal of the American Medical Association. 2002 Jun 12; 287(22):2968-72.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

CONTEXT: Among patients with abdominal aortic aneurysm (AAA) who have high operative risk, repair is usually deferred until the AAA reaches a diameter at which rupture risk is thought to outweigh operative risk, but few data exist on rupture risk of large AAA. OBJECTIVE: To determine the incidence of rupture in patients with large AAA. DESIGN AND SETTING: Prospective cohort study in 47 Veterans Affairs medical centers. PATIENTS: Veterans (n = 198) with AAA of at least 5.5 cm for whom elective AAA repair was not planned because of medical contraindication or patient refusal. Patients were enrolled between April 1995 and April 2000 and followed up through July 2000 (mean, 1.52 years). MAIN OUTCOME MEASURE: Incidence of AAA rupture by strata of initial and attained diameter. RESULTS: Outcome ascertainment was complete for all patients. There were 112 deaths (57%) and the autopsy rate was 46%. Forty-five patients had probable AAA rupture. The 1-year incidence of probable rupture by initial AAA diameter was 9.4% for AAA of 5.5 to 5.9 cm, 10.2% for AAA of 6.0 to 6.9 cm (19.1% for the subgroup of 6.5-6.9 cm), and 32.5% for AAA of 7.0 cm or more. Much of the increased risk of rupture associated with initial AAA diameters of 6.5-7.9 cm was related to the likelihood that the AAA diameter would reach 8.0 cm during follow-up, after which 25.7% ruptured within 6 months. CONCLUSION: The rupture rate is substantial in high-operative-risk patients with AAA of at least 5.5 cm in diameter and increases with larger diameter.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.