Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Variability in measurement of abdominal aortic aneurysms. Abdominal Aortic Aneurysm Detection and Management Veterans Administration Cooperative Study Group

Lederle FA, Wilson SE, Johnson GR, Reinke DB, Littooy FN, Acher CW, Messina LM, Ballard DJ, Ansel HJ. Variability in measurement of abdominal aortic aneurysms. Abdominal Aortic Aneurysm Detection and Management Veterans Administration Cooperative Study Group. Journal of vascular surgery : official publication, the Society for Vascular Surgery [and] International Society for Cardiovascular Surgery, North American Chapter. 1995 Jun 1; 21(6):945-52.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

PURPOSE: The purpose of this study was to report interobserver and intraobserver variability of computed tomography (CT) measurements of abdominal aortic aneurysm (AAA) diameter and agreement between CT and ultrasonography observed in the course of a large, multicenter, randomized trial on the management of small AAAs. METHODS: CT measurements of AAA diameter from participating centers were compared with measurements made from the same scan by a central laboratory. Blinded central remeasurement of a randomly selected subset of these CT scans was used to assess intraobserver variability. Agreement between AAA measurements by CT and ultrasonography done within 30 days of each other was also assessed. RESULTS: For interobserver pairs of local and central CT measurements of AAA diameter (n = 806), the difference was 0.2 cm or less in 65% of pairs, but 17% differed by at least 0.5 cm. For intraobserver pairs of central CT remeasurements (n = 70), 90% differed by 0.2 cm or less, 70% were within 0.1 cm, and only one differed by 0.5 cm. Of 258 ultrasound-measured and central CT pairs, the difference was 0.2 cm or less in 44% and at least 0.5 cm in 33%. Ultrasound measurements were smaller than central CT measurements by an average of 0.27 cm (p < 0.0001). Local CT and ultrasound measurements showed a marked preference for recording by half centimeter. CONCLUSIONS: A high degree of precision is possible in CT measurement of AAA diameter, but this precision may not be obtained in practice because of differences in measurement techniques. Differences between imaging modalities increase variability further. Variations in AAA measurement of 0.5 cm or more are not uncommon, and this should be taken into account in management decisions. Efforts to reduce variation in measurement are warranted and might include (1) seeking agreement between surgeons and radiologists on a precise definition of AAA diameter, (2) limiting the number of radiologists who measure AAAs, and (3) use of calipers and magnifying glass for CT measurements.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.